The procedure entry point could not be located in the dynamic link library vcruntime140 DLL

I'm on Windows 8.1 64 bit. I'm having a problem while running Mafia 3 game. The error initially was about some dll missing. I got them from dll-files.com. Like I got 13 missing dlls (file name like api-win-ms-crt-*-l1-1-0.dll) from there and copied them to game directory. Now the final error pops up while opening the game is the procedure entry point could not be located in the dynamic link library vcruntime140.dll I wasted a whole day and found that the files msvcp140.dll and vcruntime140.dll are coming from installing ms visual c++ 2015 redistributable. I tried windows update, re-installing vc++ 2015, and the OS itself several times and the problem still exists. Please help me. I donno where I'm going wrong. I'm really into playing the game.

Thanks in advance.

Edit: If this question is asked in the wrong site, forgive me. Suggest me where I can ask these kinda questions.

asked Oct 13, 2016 at 6:25

The procedure entry point could not be located in the dynamic link library vcruntime140 DLL

La CorazónLa Corazón

1251 gold badge1 silver badge9 bronze badges

I resolved the issue LOL. The problem was with the Visual C++ 2015 as I said. But inorder to install Visual C++ 2015, I had to update Windows completely. I did 2 GB of Windows Update. Then uninstalled VC++ 2015 and reinstalled. Files with name api-win-ms-crt-*-l1-1-0.dll were part of the windows update. Now game’s working. But framerate is low. My GPU is a not fast enough.

answered Oct 13, 2016 at 13:02

The procedure entry point could not be located in the dynamic link library vcruntime140 DLL

La CorazónLa Corazón

1251 gold badge1 silver badge9 bronze badges

Looking for an easy way to fix – the procedure entry point could not be located? You are at the right place. In this post we will discuss how to resolve, “The procedure entry point could not be located in the dynamic link library” error. 

The procedure entry point could not be located in the dynamic link library vcruntime140 DLL

Before getting into details, let us understand what is software entry point, and what causes the procedure entry point message. 

What is Software Entry Point?

In simple words, Software Entry Point is the starting point from where the execution of the instructions begins, and where the program has to access command-line arguments. 

For example, if you want to open a web browser, you will give the command. So that is the entry point when instructions are passed to launch the browser. However, if the entry point is not detected, it is corrupt or damaged, then you will be thrown up with the message: the procedure entry point could not be located.

Reasons For The Procedure Entry Point Skidrow Could Not Be Located In The Dynamic Link Library

Though the root cause of the problem is not yet figured out. Still, there are some common reasons for procedure entry point could not be located in the dynamic link library. 

  • A DLL goes missing.
  • The library is not found in the specific file.
  • The DLL library required to run to the program is not located. 
  • Program or driver fails to locate a specific DLL. 

Fortunately, the dynamic link library could not be located, error can be fixed using the following methods. 

Ways To Fix The Procedure Entry Point Could Not Be Located In The Dynamic Link Library Windows 10

From the above explanation, it is clear, the error occurs when the DLL file goes missing or corrupt, the system cannot locate it into the specified path, and more. The best way to avoid such problems in the future is to keep the system optimized. But, how to do that is a big question. For this, you can either try using the best PC optimization tools explained in our previous post or can give Advanced PC Cleanup a try. 

This all-in-one PC cleanup tool helps fix invalid registry entries, junk files, and cluttered data, the main reason for most of the error messages. Also, it helps clean malware infections, manage startup items, uninstall applications without leaving leftovers, and more. To know more about this tool read the detailed reviews and click the Download button to install it on your machine. 

The procedure entry point could not be located in the dynamic link library vcruntime140 DLL

Now, let us learn about the fixes that will help troubleshoot the procedure entry point error.

Solution 1: Reinstall the Program

In several cases, it has been found that the required DLL is corrupt during installation. Therefore, the best way to fix the procedure entry point skidrow that could not be located in the dynamic link library is to reinstall the program. To uninstall a program without leaving leftovers, you can try any of the best uninstallers mentioned in our previous post. Alternatively, you can get a new DLL file from another PC running the same operating system. 

Solution 2: Scan the system using updated Antivirus

Viruses and malware are the biggest culprits for altering data, including DLL files. Therefore, scanning the system for malicious files and threats is recommended. For this, you can try the Malware Protection module offered by Advanced PC Cleanup or can pick any security tool from the list of best antiviruses for Windows. 

To scan the system using Advanced PC Cleanup, follow the steps below:

1. Download and install Advanced PC Cleanup 

The procedure entry point could not be located in the dynamic link library vcruntime140 DLL

2. Run the program and click Malware Protection under Security

The procedure entry point could not be located in the dynamic link library vcruntime140 DLL

3. Click Scan Now to scan the system for malware, virus, and other nasty threats. 

4. Once the scanning is done, click Clean Now to quarantine all the detected threats. 

5. Thereafter, restart the system and then try to relaunch the program to check if the “procedure entry point could not be located” issue is fixed. If it exists, move to the next solution.

Solution 3: Re-Register the DLL File

The DLL file is the straightforward reason for entry point not found error. Hence, to fix this issue, we can try re-registering the specific file mentioned in the error message. To do so, follow the steps below:

1. Type command prompt in Windows search bar 

2. Select the best result > right-click > Run as administrator

The procedure entry point could not be located in the dynamic link library vcruntime140 DLL

3. In the Command Prompt window, type regsvr32 followed by the name of the DLL you want to re-register > Enter.

For further clarification refer to the screenshot below: 

The procedure entry point could not be located in the dynamic link library vcruntime140 DLL

4. Once the DLL is re-registered, try to launch it. This should help fix the procedure entry point that could not be located. In case the problem persists, move to the next step.

Solution 4: Use System File Checker Tool

DLL file is a type of system file. With that said, when you face any issue with the DLL try running the System File Checker command. This command scans the system for corrupt system files and fixes them automatically. To run the command, follow the steps below:

  • Open elevated Command Prompt (In administrator mode)
  • Type sfc /scannow command > Enter.
  • Wait for the scanning to finish. Once the corrupt files are repaired, restart the system to apply changes. 
  • Now try to launch the application using which you were getting, the procedure entry point could not be located in the dynamic link library, error on Windows 10. 
  • The application should launch swiftly. 

Solution 5: Perform System Restore

If none of the solutions have worked so far, we can try performing a System Restore. This will help bring back the system to the previous status before, “the procedure entry point could not be located in dynamic link library” issue. 

Note: This solution will only work if a System Restore point is created. If you have one, follow the steps below.

Additional Tip

Irrespective of what happens on your system, to ensure your sensitive data stays protected, using the best disk cloning software is recommended. For this, you can try using EaseUS Todo Backup. 

This advanced disk cloning and backup tool allows creating a backup and saving it on the same or external device. What’s more, it even supports advanced cloning actions and it is also available to try for free for 30-days. 

To install it on your system and keep your data safe, click the download button. 

The procedure entry point could not be located in the dynamic link library vcruntime140 DLL

1. In the Windows search bar, type restore and select Create a restore point.

The procedure entry point could not be located in the dynamic link library vcruntime140 DLL

2. Click System Protection tab > System Restore.

The procedure entry point could not be located in the dynamic link library vcruntime140 DLL

3. In the new window that opens click Next.

The procedure entry point could not be located in the dynamic link library vcruntime140 DLL

4. Select the restore point to which you want to restore the system > Next 

Tip: To see what all programs will be affected, click Scan for affected programs.  

5. Click the Finish button to execute it.

Doing so will restore the system. Now try to run the program using which you were facing the error, could not be located in the dynamic link library. This should fix the error message. 

Frequently Asked Questions

Q1. How do you fix the procedure entry point could not be located in dynamic link library?

To fix this error, you can follow the steps explained below:

  • Reinstall the problematic program.
  • Clean invalid registry files using Advanced PC Cleanup
  • Run System File Checker.
  • Re-register the DLL file.
  • Scan and clean malware and virus from the system
  • Perform System Restore

Q2. How do I fix the procedure entry point could not be located in the dynamic link library kernel32 DLL?

The best way to fix the procedure entry point could not be located in the dynamic link library kernel32 DLL, is to download and install the latest Windows update.

Q3. How do I fix the procedure entry point not found?

  1. Clean invalid registry files using Advanced PC Cleanup
  2. Run System File Checker.
  3. Reinstall the program using which you are facing the problem
  4. Re-register the DLL file.
  5. Scan and clean malware and virus from the system
  6. Perform System Restore

We hope you find the article useful in resolving the procedure entry point that could not be located in the dynamic link library. To learn more about such errors and how to fix them, you can read our How-To articles.

Also, if you encountered it, the procedure entry point could not be located in the dynamic link library on Windows 10, earlier. Let us know how you fix it in the comments section. Also, share your feedback and suggestions. 

How do I fix VCRUNTIME140 dll not found?

How to Fix VCRUNTIME140..
Re-register the VCRUNTIME140 DLL file..
Run System File Checker..
Reinstall the latest Visual C++ Redistributable for Visual Studio 2015..
Repair Microsoft Visual C++ 2015 Redistributable..
Run a PC repair tool..
Reinstall the program that cannot be launched..

How do you fix the procedure entry point could not be located in dynamic link library?

How To Fix “The Procedure Entry Point Could Not Be Located” in Windows 10.
Method 1. Reinstall the Problematic App..
Method 2. Use the System File Checker..
Method 3. Check the Event Viewer for Errors..
Method 4. Re-Register the DLL File..
Method 5. Scan Your Computer With Windows Defender..
Final Thoughts..
You May Also Like..

How do I fix the procedure entry point could not be located in the dynamic link library ADVAPI32 dll?

On some versions of Windows, the error "CreateProcessWithTokenW could not be located in the dynamic link library ADVAPI32. dll" can be solved by installing the Adobe Acrobat and Reader update. Run a virus/malware scan of your entire system.

Where is the VCRUNTIME140 dll located?

VCRUNTIME140. DLL is a Microsoft C Runtime Library application extension of os size around 86 KB, located in the System32 folder, and is installed by Microsoft Visual Studio. If any DLL file goes missing or gets corrupted, you can see such error messages on your screen.